I. Definition and Delimitation of Power Line Protection Zones
A transmission line protection zone, also known as a power facility protection zone, is a specific area designated in accordance with national laws and regulations to ensure the safe and stable operation of transmission lines. It is intended to prevent risks such as external damage, trees growing too tall, and buildings coming too close to the lines. There are two common methods of demarcation: the protection zone for overhead transmission lines is defined as the area within two parallel planes formed perpendicular to the ground, extending a certain distance outward from the outer edge of the line’s conductors. The extension distance varies by voltage level; for example, 10 meters beyond the outer edge of a 110 kV line and 15 meters for a 220 kV line; Protection zones for underground cable lines typically consist of a specific surface area on either side of the cable line, such as 0.75 meters or as specified by local regulations.
II. The Meaning of “Compressed Channel”
“Corridor compression” refers to the reduction in available space within a transmission corridor (the space beneath and around a transmission line designated for passage or construction) due to encroachment or crowding caused by factors such as urban development, land development, and infrastructure construction. Specifically, this manifests as: insufficient safety distances from buildings and structures; trees and vegetation encroaching into the protection zone; construction machinery and temporary structures located too close to the lines; and land within the protection zone being rezoned for other uses, such as road construction or building development. This creates safety hazards, impedes line operation and maintenance, and may even lead to power outages or safety incidents, posing a serious threat to the power supply and public safety.
III. Main Reasons for Channel Compression
First, urban expansion and limited land resources have led to power transmission lines being surrounded by various functional zones during urban development; the high value of land has resulted in high-density development that neglects the protection of power corridors. Second, there is a lack of planning coordination; power grid planning is insufficiently integrated with urban and rural planning, land use planning, and transportation planning, leading to inadequate early reservation of line corridors. Third, awareness of the need for protection is weak; organizations and individuals do not fully recognize the importance of protecting power facilities, and the low cost of violations combined with insufficient enforcement has led to frequent violations; Fourth, there is a conflict between trees and power lines: trees near overhead lines that exceed safe heights are prone to coming into contact with conductors, and in some areas, greening policies conflict with the protection of power line corridors, making it difficult to address tree-related issues in a timely manner.
IV. Risks and Consequences of Channel Compression
In terms of safety hazards, this can cause line arcing, circuit breakers to trip, and short circuits; in extreme cases, it can lead to fires and electric shock. Regarding operational and maintenance challenges, restricted access makes it difficult for inspection vehicles and personnel to enter, increasing the difficulty and risk of fault repair; In terms of grid stability, long-term obstruction or occupation of key corridors can create “bottlenecks” in grid operations, affecting the reliability of power supply across wide areas; regarding legal and economic disputes, unauthorized construction may trigger compensation claims, and grid operators must incur additional costs to ensure safety through modifications, raising transmission towers, and relocating power lines.
V. General Approach to the Solution
Using Dingxin Smart Technology’s power transmission line corridor video surveillance device—the AI PTZ camera DX-WPS100-SP—which centers on video monitoring and integrates multiple advanced technologies, the system enables comprehensive, real-time monitoring of power transmission lines. This allows for the timely detection and resolution of various issues caused by corridor encroachment, ensuring the stable operation of the lines.
(1) System Configuration and Power Supply Method
System Components
The system primarily consists of a main control unit, a communication module, a power supply module, an AI PTZ dome camera, and a wireless transmission unit. These modules work together, with the main control unit responsible for overall coordination and control; the communication module ensuring data transmission; the power supply module providing stable power; the AI PTZ dome camera capturing video; and the wireless transmission unit enabling remote data transmission.
Power Supply Method
It uses a dual-power supply system consisting of solar energy and a lithium-ion battery. During the day, the solar panels absorb light and convert it into electrical energy to power the device and charge the lithium-ion battery; at night or when there is insufficient sunlight, the lithium-ion battery powers the device, ensuring 24-hour uninterrupted operation.
(2) Core Features and Technical Advantages
Video Capture and Monitoring Features
1. High-Definition Video Viewing: Features 2-megapixel high-definition real-time video viewing with a resolution of ≥1080p, providing clear real-time images of power line corridors, tower bases, and sites with potential hazards, and offering intuitive visual information to operations and maintenance personnel.
2. 3D Panoramic View: Equipped with an omnidirectional PTZ camera capable of 360° horizontal and ±90° vertical rotation, it provides panoramic surveillance. The camera features continuous 360° horizontal rotation with an adjustable speed ranging from 0.6 to 200°/s, allowing for flexible adjustment of the monitoring angle and comprehensive coverage of the areas surrounding the power transmission lines.
3. Starlight Full-Color Night Vision: Utilizes industrial-grade super starlight night vision technology with a minimum illumination of 0.001 lux, delivering clear, full-color images even in complete darkness to ensure uninterrupted nighttime surveillance.
Monitoring and Identification Functions
1. Beyond-Line-of-Sight Dynamic Patrol: Offers a choice of 40x or 20x hybrid zoom, with up to 255 preset positions and 16 patrol routes. Operations and maintenance personnel can configure preset positions and patrol routes according to actual needs to enable automatic patrols, thereby improving patrol efficiency and expanding the patrol coverage area.
2. Intelligent Video Detection of Potential Hazards: Utilizing lightweight, low-power AI algorithms, this system can intelligently detect potential hazards on the device side. It can quickly and accurately identify situations where construction machinery, temporary structures, or piles of debris are located near power lines, as well as potential hazards such as overgrown trees and wildfires, and issue timely warnings.
3. “AI + Video” Operating Mode: For specific hazards such as wildfires, the “AI + Video” operating mode can be activated to record video evidence. AI algorithms intelligently identify and analyze wildfires while simultaneously recording video evidence, providing strong support for subsequent handling.
Data Transmission and Access Functions
1. Edge Data Collection and Processing: The device is equipped with a wide range of interfaces, including Wi-Fi, Bluetooth, RS485, and Ethernet ports, enabling the collection of status-sensing data at the edge. It can connect to various sensors to collect environmental data such as temperature, humidity, and wind speed, providing additional information for a comprehensive assessment of the operational status of power transmission lines.
2. Standard Power Grid Protocol Integration: Supports standard power grid protocols, enabling seamless integration with the internal network’s unified video platform. This facilitates centralized management and analysis of surveillance data by power grid companies, enables data sharing and collaboration with other power systems, and improves the overall operational management of the power grid.
Video Recording and Security Features
1. 24-hour continuous front-end recording: Supports continuous front-end recording, with recordings overwritten on a looping basis to ensure that important video data is not lost. Historical recordings can be retrieved at any time to provide evidence for accident analysis and liability determination.
2. Optional built-in encryption chip: The device can be equipped with an optional security encryption chip that encrypts transmitted data to ensure its security during transmission. This prevents data from being stolen or tampered with, ensuring the secure and stable operation of the power monitoring system.